nivelco

EasyTREK SP-500

  • The new EasyTREK SP-500 series ultrasonic level transmitters are available to order from the end of June.
    The members of the new EasyTREK SP-500 series can be recognised from the more compact size, and the increased maximum measuring distance in the specific price range.


   NIVOCAP CK - (RF Capacitance) : LEVEL SWITCHES

FEATURES :
  • Short description: Intelligent radio-frequency (130 kHz) level switch for liquids, powdered or granular solids
  • Operating principle: The electronics evaluates continuously the voltage level proportional to the capacitance difference between the two probes and the housing.
  • Setting of the switching point(s): Selectable sensitivity from 4 ranges, fine tuning with potentiometer within the selected range.
  • Material of wetted parts: Stainless stel, PP
  • Housing material: Alu cast
  • Ex version: Available (Dust Ex)

APPLICATION CONSIDERATIONS :
  • For solids with εr ≥ 1,5 relative dielectric constant and liquids
  • Special applications: For adhering, sticky materials
  • Suggested applications: Limit switch, high or low fail-safe switching
  • Measurable mediums: Sludge, highly contaminated liquids, foams, grain, animal feed, sand, soot, cement, granules etc.

TECHNICAL DATA :
  • Power supply: 20-255 V AC/DC
  • Ambient temperature: -30°C ... +60°C
  • Medium temperature: -30°C ... +235°C
  • Process pressure: max. 25 bar
  • Process connection: ¾”, 1”, 1 ½” BSP/NPT
  • Output: Relay (SPDT) or electronic switch (SPST)
  • Protection: IP67
  • Ex marking: ATEX II 1/2 D Ex ta IIIC T85°C…T220°C Da/Db



       Print...
 
FEATURES

  • Intelligent electronic level switch
  • Not sensitive to deposits
  • Easy calibration with LED display
  • Calibration with external magnet without removing the housing cover
  • Selectable sensitivity
  • Fail-safe operation mode
  • Rod or cable extended versions
  • High temperature version
  • Selectable response time between 0 - 15 sec
  • Vibration-resistant electronic output
  • Dust-Ex models

APPLICATIONS

  • For solids with εr≥1.5 and liquids
  • For adhering, sticky materials
  • Pharmaceutical and Food industry
  • Power generation processes

SPECIFICATIONS

  • Power supply: 20-255 V AC/DC
  • Ambient temperature: -30°C ... +60°C
  • Medium temperature: -30°C ... +235°C
  • Process pressure: max. 25 bar
  • Process connection: ¾”, 1”, 1 ½” BSP/NPT
  • Output: Relay (SPDT) or electronic switch (SPST)
  • Protection: IP67
  • Ex marking: ATEX II 1/2 D Ex ta IIIC T85°C…T220°C Da/Db


       Print...



 
FEATURES ::
  • Intelligent electronic level switch
  • Not sensitive to deposits
  • Easy calibration with LED display
  • Calibration with external magnet without removing the housing cover
  • Selectable sensitivity
  • Fail-safe operation mode
  • Rod or cable extended versions
  • High temperature version
  • Selectable response time between 0 - 15 sec
  • Vibration-resistant electronic output
  • Dust-Ex models
APPLICATIONS ::
  • For solids with εr≥1.5 and liquids
  • For adhering, sticky materials
  • Pharmaceutical and Food industry
  • Power generation processes
SPECIFICATIONS ::
  • Power supply: 20-255 V AC/DC
  • Ambient temperature: -30°C ... +60°C
  • Medium temperature: -30°C ... +235°C
  • Process pressure: max. 25 bar
  • Process connection: ¾”, 1”, 1 ½” BSP/NPT
  • Output: Relay (SPDT) or electronic switch (SPST)
  • Protection: IP67
  • Ex marking: ATEX II 1/2 D Ex ta IIIC T85°C…T220°C Da/Db




Colour Brochure  Mb.  
hu
NIVOCAP CK 9,55 
en
NIVOCAP CK 8,99 
cz
NIVOCAP CK 9,17 
hr
NIVOCAP CK 9,36 
User's Manual  Mb.  
hu
NIVOCAP CK-100 0,44 
en
NIVOCAP CK-100 0,41 
 
Programming Manual  Mb.  
-
Product Certificates  Mb.  
ATEX
NIVOCAP CK 5,53 
IEC
NIVOCAP CK 1,59 
DoC
EU declaration of conformity - ATEX 0,22 
DoC
EU declaration of conformity 0,21 

Download drawings in DXF format :  Download
Code numberDescriptionProcess connection2D PDF2D JPG3D
CK[DG]-1__Standard version - max 0.6 m3/4 BSP / NPTCK[DG]-1__CK[DG]-1__CK[DG]-1__
CK[EF]-1__Rod extended version - max. 1,5 m3/4 BSP / NPTCK[EF]-1__CK[EF]-1__-
CK[HN]-1__Standard version - max 0.6 m1 1/2 BSP / NPTCK[HN]-1__CK[HN]-1__CK[HN]-1__
CK[KC]-1__Cable extended version - max 10m1 1/2 BSP / NPTCK[KC]-1__CK[KC]-1__CK[KC]-1__
CK[MP]-1__Standard version - max 0.6 m1 BSP / NPTCK[MP]-1__CK[MP]-1__CK[MP]-1__
CK[VZ]-1__Rod extended version - max 3m1 BSP / NPTCK[VZ]-1__CK[VZ]-1__-
CKR-1__Rod extended version - max 3m1 1/2 BSP / NPTCKR-1__CKR-1__-
CM[DG]-1__High temp. version - max 0.6 m3/4 BSP / NPTCM[DG]-1__CM[DG]-1__CM[DG]-1__
CM[EF]-1__High temp. , rod extended - max 1.5 m3/4 BSP / NPTCM[EF]-1__CM[EF]-1__-
CM[HN]-1__High temp. version - max 0.6 m1 1/2 BSP / NPTCM[HN]-1__CM[HN]-1__CM[HN]-1__
CM[MP]-1__High temp. version - max 0.6 m1 BSP / NPTCM[MP]-1__CM[MP]-1__CM[MP]-1__
CM[RL]-1__High temp. , rod extended version - max 3m1 1/2 BSP / NPTCM[RL]-1__CM[RL]-1__-
CM[VZ]-1__High temp. , rod extended version - max 3m1 BSP / NPTCM[VZ]-1__CM[VZ]-1__-
























2017 - Budapest Waterworks, Hungary :: Distributor: NIVELCO CO.

The dry sludge (with about 30% humidity) resulted by the centrifuge is forwarded with a screw transporter to a collecting hopper and then it is pumped alternately into the currently empty one of the five storage silos. For the hopper controlling, a continuous level transmitter is used, but the ultrasonic transmitter with analogue 4-20 mA output doesn’t provide 100% reliable measurement due to the small measuring range, and the false reflections caused by the small space. This is why NIVELCO’s NIVOCAP CKM-103-1 high-frequency capacitance level switch has been installed next to the hopper control level meter for the purpose of high fail-safe level indication.

Read more ... Budapest Waterworks, Hungary

  Nivelco's instruments:
  • NIVOCAP CKM-103-1

      

  
292,553 


2016 - Konstanca, SARGEANT MARINE ROMANIA S.R.L., Románia

The end-user SARGEANT MARINE ROMANIA S.R.L. is an England-based company having leading role in the Romanian road construction industry for nearly 20 years considering the amount of produced bitumen. The company’s facility is located in Constanța in the coast of the Black Sea where the bitumen is stored in 7 high capacity (9000 m3) tanks. The measurement task was the following:
  • Continuously measure the stored volume in the tanks
  • Temperature measurement in three points inside the tank
  • Providing high fail-safe alarm with sound and visual indication
  • Local displaying of the measurement data
  • Collecting and logging the data in a central computer
  • Volume correction based on the measured temperature


Read more ... PILOTREK & NIVELCO CK application in romania

  Nivelco's instruments:
  • PiloTREK WHS-150-4 – 1 pc
  • PiloTREK WJS-182-4 – 6 pcs
  • THERMOCONT TBC-526-4 – 21 pcs
  • NIVOCAP CMV-115-1 – 7 pcs
  • MultiCONT PRD-2MA-1 – 3 pcs
  • NIPOWER PPK-331-1 – 2 pcs
  • NIVISION process visualization software

      

    
285,446 


2016 - Nirlat, Israel :: Distributor: Technomad Industrial Instruments and Control Ltd.

Nirlat is one of the largest and leading Israeli industrial companies specializes in the development, and manufacture paint, decorative paint, powder, surface preparation compounds and sealants. Nowadays, as part of Israel south region development, Nirlat’s factory is replacing old production lines with new ones including all level transmitters & switches.

Read more ... NIVELCO instruments in the Israeli pait factory

  Nivelco's instruments:
  • EasyTREK SCD-34J-4 – 4 pcs
  • PiloTREK WPM-140-8 Ex – 12 pcs
  • NIVOCONT RKH-502-5 Ex – 12 pcs
  • NIVOCONT RKR-510-5 Ex – 4 pcs
  • NIVOSWITCH RCM-406-9 Ex – 8 pcs
  • NIVOCAP CKV-115-5 Ex – 4 pcs
  • NIVOSWITCH RCM-401-4 – 2 pcs
  • NIVOSWITCH RCM-401-3 – 4 pcs

    
285,436 


2015 - Budapest Central Wastewater Treatment Plant, Hungary, Budapest

In the Budapest central wastewater treatment plant - like in every other wastewater plant - the sludge extraction and storage is an important task. After the centrifuge of the dry sludge (with about 30 % humidity) it is forwarded with a screw transporter to a collecting hopper and then it is pumped alternately into one of the currently empty five storage silos. A NIVOCAP CK high-frequency capacitance level switch is installed next to the hopper control level meter for the purpose of high fail-safe level indication which stops the screw transporter to prevent overfill.

  Nivelco's instruments:
  • NIVOCAP CKM-103-1

      

    
257,081 


Copyright 1994-2015 Nivelco zRt. All Rights Reserved.